==System-hardware requirements== | ==System-hardware requirements== | ||
* operating system MS Windows 8, Windows 7, Vista, XP | * operating system MS Windows 10, Windows 8, Windows 7, Vista, XP | ||
* 2 GHz dual core processor | * 2 GHz dual core processor | ||
* 2 GB RAM for Win XP or 3 GB RAM for Win8, Win7 or Vista | * 2 GB RAM for Win XP or 3 GB RAM for Win10, Win8, Win7 or Vista | ||
* minimum screen resolution 1280x1024 | * minimum screen resolution 1280x1024 | ||
* Microsoft.NET Framework 4 is required | * Microsoft.NET Framework 4 is required | ||
Latest revision as of 13:14, 25 March 2017
| Product | NetSystem 4 |
| Type of article | PRODUCT INFORMATION |
| Source for translation | NS 4.7 |
System-hardware requirements
- operating system MS Windows 10, Windows 8, Windows 7, Vista, XP
- 2 GHz dual core processor
- 2 GB RAM for Win XP or 3 GB RAM for Win10, Win8, Win7 or Vista
- minimum screen resolution 1280x1024
- Microsoft.NET Framework 4 is required
- Internet access for activation and updating of the software and directories is recommended
- installation and later usage with the same user righs is recommended
List of standards and methods used for sizing and calculations
Net-san
Gravity sewerage
- Stream of stormwater (Qd):
- PN EN 752-4 Standard
- Karl and Klauss R. Imhoff: Urban Drainage and Wastewater Disposal.
- Hydraulic calculations of partly filled pipes (Qs, Qd):
- flow calculation due to Bretting’s formula.
- pressure drop calculation due to Prandtl-Colebrook formula.
- Self-defecation:
- due to the method of boundary shear stress.
- Pipe diameter sizing:
- considering sum of streams (Qs and Qd) and fill ratio.
- Network arrangement:
- authorized method which meets required minimum and maximum depth gradient and collisions with other networks.
- Local friction:
- considering roughness of pipes taken from catalogue data or from ATV-DVWK A110P standard.
Pressure sewerage
- Pumping stations:
- based on: Karl and Klauss R. Imhoff: Urban Drainage and Wastewater Disposal and authorised method.
- Hydraulic calculations of completely filled pipes:
- due to Colebrooke-White’s formula, Qs and Qd values are directly added up.
- Pipe diameter sizing:
- considering the maximum speed (Vmax) and the maximum unconsolidated frictional resistance (Rmax) values.
- Network arrangement:
- authorized algorithm considering the boundary conditions (min/max cover and declines), and collisions.
- Local friction:
- not considered.
Water pipeline
- Calculations of pipes completely filled:
- due to Colebrooke-White’s formula.
- Pipe diameter sizing:
- considering the maximum speed (Vmax) and the maximum unconsolidated frictional resistance (Rmax) values.
- Network arrangement:
- authorized algorithm considering the boundary conditions (min/max cover and declines), and collisions.
- Local friction:
- enabled by the ability of declaring dzeta value for water pipe network junction.