| Product | InstalSystem 5 |
| Type of article | PRODUCT INFORMATION |
| Source for translation | BETA REV. 2.0.B4 |
Technical requirements
Minimum hardware requirements
- Processor: 2-core processor, x86 architecture
- RAM: 4 GB
- Graphics card: 512 MB VRAM
- Hard disk space: approx. 1 GB free space
- Screen resolution: 1366x768
- Mouse with scroll function
Recommended hardware requirements
- Processor: 4-core processor, x86 architecture
- RAM: 8 GB
- Graphics card: 2 GB VRAM
- Hard disk space: approx. 1 GB free space per Rev.
- Screen resolution: 1920x1080 or 2 display monitors
- Mouse with scroll function
System requirements
- Windows 7, Windows 8, Windows 10 (64-bit systems)
User right required
- When installing for all users of a given computer an account with administrator rights is required.
- When installing for the current user a standard user account is required.
Other requirements
- Microsoft.NET Framework 4.6 or higher
- Internet access required for activation and updating
- Constant Internet access required to be able to use on-line help (optional)
List of standards and methods used for sizing and calculations
Heating and cooling installations
Radiant systems design
- Supply temperature optimization - proprietary method
- Thermal calculations (heating and cooling) - EN 1264
Pipeline network calculations
- Hydraulic calculations - Darcy and Colebrook equations
- Diameter sizing - R_max and v_max criteria
- Hydraulic balancing - proprietary method
- Heat loss in pipelines - according to professional literature
- Pipeline insulation sizing - EnEv (German) or WT2008 (Polish) recommendations, depending on the market-language version