How to eliminate problems with radiant system loops

From HelpSystem
Revision as of 15:44, 26 July 2016 by X - TIEMME IT (talk | contribs) (Odpowiedz TP na Case 165515)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Product InstalSystem 5
Type of article TYPICAL PROBLEM
Source for translation IS 5.0 Beta 31


Problem description

Problems associated with automatic generation of pipe feeds using the Pipe feeds route tool are diagnosed by means of the following message:

  • Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually.

The message informs that pipe feeds could not be generated automatically by means of the Pipe feeds route tool, due to the following reasons:

  • specified or automatically sized arrangement spacings are too large,
  • manner of component crossing Pipe feeds route is inappropriate (for the algorithm of automatic pipe feed arrangement),
  • number of component crossings Pipe feeds route is too large,
  • Pipe feeds route components are located too close to each other,
  • width of the strip within which Pipe feeds route generates pipe feeds is too small or too large (reaches beyond the borders of the heating zone).

Solution

  • Specify smaller pipe feed arrangement spacing.