Release notes InstalSystem 5: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
No edit summary
No edit summary
Line 22: Line 22:
====Modules:====
====Modules:====
'''InstalSystem basis and Package Manager'''
'''InstalSystem basis and Package Manager'''
* Dodano formaty A0 i A1 dla stron wydruku.
* Added A0 and A1 formats to printout pages.
* Usprawniono działanie trybów AUTO i ORTO.
* Improved AUTO and ORTO modes.


'''Radiator sizing'''
'''Radiator sizing'''
* Dodano możliwość wyświetlania nastawy wkładki zaworowej w etykiecie grzejnika.
* Added possibility to display in radiator’s label setting of valves insert.
* Udostępniono w danych ogólnych możliwość definiowania domyślnej odległości grzejników od ściany.
* Allowed defining in project options default distance of radiator from wall.
* Ulepszono prezentację graficzną elementów mocowania grzejników (tzw. konsoli) na rzutach.
* Improved graphical presentation of radiators mounting items (so-called consoles) on plan views.


'''Radiant loop systems'''
'''Radiant loop systems'''
* Dodano możliwość wyboru kryterium optymalizacji temperatury zasilania w systemach płaszczyznowych z korektą działania algorytmu.
* Added possibility to choose criterion of supply temperature optimization in radiant systems with correction of the algorithm's operation.
* Usprawniono algorytm automatycznie generujący rysunki pętli o.p./ch.p.
* Improved algorithm of automatic division Heating/Cooling Zones into Heating/Cooling Areas.
* Usprawniono algorytm automatycznego podziału stref na powierzchnie grzewczo-chłodzące.
* Improved algorithm of automatic drawings of radiant heating/cooling loops.


====Articles in HelpSystem:====
====Articles in HelpSystem:====

Revision as of 11:35, 16 January 2018

Product InstalSystem 5
Type of article PRODUCT INFORMATION
Source for translation GOLD Rev. 6.1


Information about changes

Version GOLD Rev. 6.1

Modules:

InstalSystem basis and Package Manager

  • Added A0 and A1 formats to printout pages.
  • Improved AUTO and ORTO modes.

Radiator sizing

  • Added possibility to display in radiator’s label setting of valves insert.
  • Allowed defining in project options default distance of radiator from wall.
  • Improved graphical presentation of radiators mounting items (so-called consoles) on plan views.

Radiant loop systems

  • Added possibility to choose criterion of supply temperature optimization in radiant systems with correction of the algorithm's operation.
  • Improved algorithm of automatic division Heating/Cooling Zones into Heating/Cooling Areas.
  • Improved algorithm of automatic drawings of radiant heating/cooling loops.

Articles in HelpSystem:

Version GOLD Rev. 5.1

  • There were no significant functional changes in this release.

Version GOLD Rev. 5.0

Modules:

InstalSystem basis and Package Manager

  • Dodano linie wymiarowe.

Radiant loop systems

  • Poprawiono algorytm automatycznego podziału SPGCh
  • Poprawiono prezentację rysunków pętli o.p. na widoku 3D.
  • Rozszerzono funkcjonalność trasy przyłączy o automatyczne wypełnianie całej szerokości pasa przyłączami.

Articles in HelpSystem:

Version GOLD Rev. 4.0

Modules:

Radiant loop systems

  • Usprawniono algorytm rysujący pętle o.p.

Radiant panel systems

  • Dodano strefę paneli - narzędzie do automatycznego układania paneli/promienników sufitowych.

Articles in HelpSystem:

Version GOLD Rev. 2.2

Modules:

InstalSystem basis and Package Manager

  • Added possibility to saved files read-only.
  • 3D view printout has been avaliable.

Articles in HelpSystem:

Version GOLD Rev. 2.1

  • There were no significant functional changes in this release..

Version GOLD Rev. 2.0

Initial scope of modules:

  • InstalSystem basis and Package Manager
  • Heat loss (thermal load)
  • Radiator sizing
  • Radiant loop systems
  • Radiant panel systems
  • Radiant loop dry systems
  • Heating systems
  • Radiant cooling systems
  • Interface gbXML (BIM)

Initial state of information materials