Release notes InstalSystem 5: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
No edit summary
(Dodanie RN dla 8.0 i 9.0 na podstawie case 203087 i case 204956 w EN)
Line 44: Line 44:
* There were no significant functional changes in this release.
* There were no significant functional changes in this release.


===Wersja GOLD Rev. 8.0===
===Version GOLD Rev. 9.0===
====Moduły:====
====Modules:====
'''InstalSystem basis and Package Manager'''
'''InstalSystem basis and Package Manager'''
* Ulepszono diagnostykę niekompletnych danych dla przypadku generowania ścian z obrysów pomieszczeń i budynku.
* Added declare multi-wing doors and windows.
* Etykieta pomieszczenia - dodano możliwość wyświetlenia pola ''<IS_TS id=Lang.Elements.Common.StrAccess.sOpis/>'' ''<IS_TS id=sERCoolOpisPomieszczenia/>''
* Added the appearance configuration of the ''Reference point''.
* Udostępniono możliwość tworzenia domyślnych typów pomieszczeń (wraz z ich danymi i parametrami).
* ''AUTO'' mode has been extended of snap the vertices ''Opening in slab'' to elements from the DWG underlay.
* Umożliwiono konfigurację wyglądu elementów podczas operacji ich wstawiania.
 
* Polepszono ergonomię uzupełniania danych elmentów graficznych.
'''Radiant loop systems'''
* Improved algorithm of insert ''Heating floor'' in multi-storey rooms (with ''Opening in slab'').
* Implemented automatic algorithm which cuts ''Heating wall'' lying in the area of windows / doors.
 
'''Heat loss (thermal load)'''
* Added the possibility of defining ''Tolerance relative to thickness of graphical partition'' (wall, ceilings and roofs), that the ''Partition definitions'' will be assign.
 
'''Radiant panel systems'''
* Improved determination of the optimal refrigerating level (deltaT) for the serial-connected panels.
* Maximum height position for the panels has been increased to 30 m.
* Expanded information of the flow rate for panel hint and panel label.
 
===Version GOLD Rev. 8.0===
====Modules:====
'''InstalSystem basis and Package Manager'''
* Improved diagnostics for incomplete data when ''Generate walls and slabs from rooms and building contour'' algorithm has launched.
* Room label - added the ability of display the ''Description'' field.
* Added the possibilty of creating default room types (with their data and parameters).
* Added configure the appearance of elements during their insertion operations.
* Improved the ergonomy of filling graphic elements data.


'''Heat loss (thermal load)'''
'''Heat loss (thermal load)'''
* Zmieniono z błędu na ostrzeżenie status diagnostyki zerowej grubości definicji przegrody o narzuconym "U". Taka definicja przypisuje się do wszystkich pasujących przypadków w projekcie, niezależenie od rysunkowej grubości ścian, co może być wykorzystane dla przyspieszenia wprowadzania danych.
* Changed diagnostics from error to warning for ''Partition definitions'' with empty thickness for ''Part. with specified U (Heat transfer coefficient)''.


===Version GOLD Rev. 7.3===
===Version GOLD Rev. 7.3===

Revision as of 16:35, 29 August 2018

Product InstalSystem 5
Type of article PRODUCT INFORMATION
Source for translation GOLD Rev. 11.0


Information about changes

Version GOLD Rev. 11.0

Moduły:

InstalSystem basis and Package Manager

  • Improved function "Generate walls and slabs from rooms and building contour".
  • Improved zoom scale and the preview scale.
  • Improved diagnostics concerning errors in the building structure.
  • Supplemented information presented in the result tables.
  • Integration of "Paper format" element with 'Printout page' element.

Radiant loop systems

  • Improved algorithm of heat output calculations of Heated by pipe feeds floor type connected virtually.
  • Improved algorithm which automatically inserts a heating/cooling floors into rooms with a hole in the slab.
  • Heating systems
  • Improved automatic connections of integrated radiators to distrubution pipes, depending on the configuration: valve shape (straight, angle) and connection direction (from the floor, from the wall).

Radiant panel systems

  • Improved flow rates calculations for the serial-connected panels.

Version GOLD Rev. 9.2

  • There were no significant functional changes in this release.

Version GOLD Rev. 9.1

  • There were no significant functional changes in this release.

Version GOLD Rev. 9.0

Modules:

InstalSystem basis and Package Manager

  • Added declare multi-wing doors and windows.
  • Added the appearance configuration of the Reference point.
  • AUTO mode has been extended of snap the vertices Opening in slab to elements from the DWG underlay.

Radiant loop systems

  • Improved algorithm of insert Heating floor in multi-storey rooms (with Opening in slab).
  • Implemented automatic algorithm which cuts Heating wall lying in the area of windows / doors.

Heat loss (thermal load)

  • Added the possibility of defining Tolerance relative to thickness of graphical partition (wall, ceilings and roofs), that the Partition definitions will be assign.

Radiant panel systems

  • Improved determination of the optimal refrigerating level (deltaT) for the serial-connected panels.
  • Maximum height position for the panels has been increased to 30 m.
  • Expanded information of the flow rate for panel hint and panel label.

Version GOLD Rev. 8.0

Modules:

InstalSystem basis and Package Manager

  • Improved diagnostics for incomplete data when Generate walls and slabs from rooms and building contour algorithm has launched.
  • Room label - added the ability of display the Description field.
  • Added the possibilty of creating default room types (with their data and parameters).
  • Added configure the appearance of elements during their insertion operations.
  • Improved the ergonomy of filling graphic elements data.

Heat loss (thermal load)

  • Changed diagnostics from error to warning for Partition definitions with empty thickness for Part. with specified U (Heat transfer coefficient).

Version GOLD Rev. 7.3

  • There were no significant functional changes in this release.

Version GOLD Rev. 7.2

Modules:

InstalSystem basis and Package Manager

  • New diagnostic messages for incorrect or incomplete building structure data have been introduced.
  • The rank of the message with zero thickness of the partition definition has been reduced to a warning or hint (when the definition has no default status).

Radiant panel systems

  • "Zone of ceiling panels" tool has been improved and developed.

Version GOLD Rev. 6.1

Modules:

InstalSystem basis and Package Manager

  • Added A0 and A1 formats to printout pages.
  • Improved AUTO and ORTO modes.

Radiator sizing

  • Added possibility to display in radiator’s label setting of valves insert.
  • Allowed defining in project options default distance of radiator from wall.
  • Improved graphical presentation of radiators mounting items (so-called consoles) on plan views.

Radiant loop systems

  • Added possibility to choose criterion of supply temperature optimization in radiant systems with correction of the algorithm's operation.
  • Improved algorithm of automatic division Heating/Cooling Zones into Heating/Cooling Areas.
  • Improved algorithm of automatic drawings of radiant heating/cooling loops.

Articles in HelpSystem:

Version GOLD Rev. 5.1

  • There were no significant functional changes in this release.

Version GOLD Rev. 5.0

Modules:

InstalSystem basis and Package Manager

  • Added dimension lines.

Radiant loop systems

  • Improved the algorithm of automatic division of heating/cooling floor zone.
  • Improved presentation of RHC loop drawing on 3D view.
  • Extended functionality of pipe feed route to automatically fill the entire width of the stip with pipe feeds.

Articles in HelpSystem:

Version GOLD Rev. 4.0

Modules:

Radiant loop systems

  • Improved the algorithm drawing the RHC loop.

Radiant panel systems

  • Added ceiling panels zone - tool for automatic stacking of ceiling panels.

Articles in HelpSystem:

Version GOLD Rev. 2.2

Modules:

InstalSystem basis and Package Manager

  • Added possibility to saved files read-only.
  • 3D view printout has been avaliable.

Articles in HelpSystem:

Version GOLD Rev. 2.1

  • There were no significant functional changes in this release..

Version GOLD Rev. 2.0

Initial scope of modules:

  • InstalSystem basis and Package Manager
  • Heat loss (thermal load)
  • Radiator sizing
  • Radiant loop systems
  • Radiant panel systems
  • Radiant loop dry systems
  • Heating systems
  • Radiant cooling systems
  • Interface gbXML (BIM)

Initial state of information materials