Release notes InstalSystem 5: Difference between revisions

From HelpSystem
Jump to navigation Jump to search
Line 264: Line 264:
* [[Appending drawings with radiant system loops]]
* [[Appending drawings with radiant system loops]]


===Versão BETA 21 Rev. 15.9.2===
===Version BETA 21 Rev. 15.9.2===
====Módulos:====
====Modules:====
'''Módulo base, incluíndo Gestor InstalSystem'''
'''Base module, including InstalSystem Manager'''
* Modificado o modo de importação de ficheiros de desenho base.
* Modified the way of importing base drawing files.
* Adicionada a função ''Selecionar componentes no retângulo'' sob o botão esquerdo do rato.
* Added a ''Select components in rectangle'' function under the left mouse button.
* Melhorada a ação do modo ''ORTO'' ao mover objetos.
* Improved acting of ''ORTO'' mode when moving objects.
* Acelerado o carregamento de ficheiros recentemente criados ou novamente gravados, como consequência os ficheiros criados em versões anteriores mais lentos a carregar.
* Accelerated loading of the newly created or saved again files, as a consequence the files created on previous versions may load slower.


'''Aquecimento radiante - sistemas em circuito'''
'''Radiant heating - loop systems'''
* Adicionada a possibilidade de ligação paralela de vários circuitos QFR para uma saída comum a partir do coletor.
* Added the possibility of parallel connection of several RHC loop to one common outlet from the manifold.
* Introduzido diagnósticos de balanço do circuito QFR ligados ao coletor com válvular de balanceamento não integradas, e a possibilidade de adicionar válvulas de tubagens que estão a balancear estes objetos.
* Introduced balance diagnostics of the RHC loop connected to the manifold with not integrated balancing valves, and the possibility of adding on the pipe-runs valves which are balancing these objects.


'''Rede de aquecimento com balanceamento'''
'''Heating network with balancing'''
* Adicionada a possibilidade de usar zona de aquecimento de pavimento multi-circuito.
* Added the possibility to use multi-circuit heating floor zone.
* Introduzido diagnóstico de balanço dos circuitos pelas zonas de aquecimento de pavimento nos sistemas sem coletor.
* Introduced balance diagnostics of the circuits by the heating floor zones in the systems without the manifold.
* Adicionada a possibilidade de alimentar zona de aquecimento de pavimento multi-circuito a partir de vários coletores.
* Added the possibility to supply multi-circuit heating floor zone from several manifolds.
* Introduzida a possibilidade de alimentar zonas de aquecimento/arrefecimento diretamente da fonte virtual ou gráfica, sem o uso de um coletor.
* Introduced the possibility of supplying heating/cooling zones directly from the virtual or graphical source, without the usage of a manifold.


====Artigos em HelpSystem:====
====Articles in HelpSystem:====
* [[Cálculo da capacidade de arrefecimento de sistemas radiantes (pavimento, parede ou teto)]]
* [[Calculation of cooling capacity for radiant systems (floor, wall or ceiling)]]
* [[Como calcular um ficheiro usando uma configuração do pacote diferente da qual em que foi criado]]
* [[How to calculate a file using a package configuration other than the one under which the file was created]]
* [[Instalação com sistema de aquecimento radiante de pavimento e parede em edifício unifamiliar]]
* [[Installation with underfloor and wall radiant heating system in single family building]]


===Versão  BETA 16.1 Rev. 15.5.17===
===Versão  BETA 16.1 Rev. 15.5.17===

Revision as of 12:38, 20 April 2017

Product InstalSystem 5
Type of article PRODUCT INFORMATION
Source for translation IS 5.0 Beta Rev. 2.0.B2


Information about changes

Version BETA Rev. 2.0.B2

Modules:

Base module

  • Fixed walls connecting generated automatically by the partitions generator.
  • Fixed connecting fragments of the underlay in .pdf format.
  • Standardized the list of kinds and types of rooms.
  • Allowed quickly switching between worksheets in a graphical editor using the arrows next to the selection window of the worksheets.

Radiant heating - loop systems

  • Moved window of control circuit settings to Thermal systems sources in the General Data.
  • Allowed to replace virtual temperature sources with graphic elements by ugins a special button in the control circuit settings in the General Data.

Version BETA Rev. 2.0.B1

Modules:

Base module

  • Introduced the ability to search elements in the Project browser based on a string of signs.
  • Allowed to insert dormers.

Articles in HelpSystem:

Version BETA 37 Rev. 0.0.B37

Modules:

Base module

  • Improved efficiency of the program in handling with complex projects, time of files upload and regeneration of the 3D view.

Radiator sizing

  • Added the ability to search of radiators and valves placed on the radiators in the search window of elements in the project.

Heat loss (thermal load)

  • Introduced heat loss (thermal load) module in accordance with standard EN 12831.

Articles in HelpSystem:

Version BETA 35 Rev. 0.0.B35

Modules:

Base module

  • Raising the ergonomics of editing the roof by multiedit few vertices at the same time.
  • Merge and trim functions identify the premises in one operation.
  • Introduced new physical elements - arched Windows and doors.
  • Introduced new physical element - Opening in slab.
  • Improved support for facilities construction if the hole in the roof.
  • Introduced new feature - Building contour.
  • Introduced the interpretation of walls based on stroke building.
  • Introduced a new feature - Partitions generator.

Articles in HelpSystem:

Version BETA 34 Rev. 0.0.B34

Modules:

Base module, including InstalSystem Manager

  • Improved import files created in InstalSystem 4 for automatic deletion of elements that are not supported in InstalSystem 5.
  • Improved Wall connection.
  • Integrated a full range of Construction processing operations.

Radiator sizing

  • Expanded radiator sizing in Addition for thermostat and Addition for casing/chanel.
  • Expanded operations on the elements Radiators about the possibility of Flip horizontal.

Articles in HelpSystem:

Version BETA 33 Rev. 0.0.B33

Modules:

Radiant heating - loop systems

  • Improved the data propagation from Room elements created with walls to the Heating/Cooling Wall Zone elements.

Radiator sizing

  • Improved the data propagation from Room elements created with walls to the Radiator elements.

Version BETA 32 Rev. 0.0.B32

Modules:

Base module, including InstalSystem Manager

  • Introduced the ability of creating rooms due to other building structure's elements inserted in the project.
  • Introduced the ability of dividing roof into parts and added new functionality which allows to change ordinates of individual points at the roof's outline to model its real surface.
  • Introduced new physical element - roof window.
  • Introduced new physical element - recess.
  • Improved evaluating the location of the elements above the plane of the floor.
  • Increased the ergonomy of label editor.

Radiator sizing

  • Introduced radiator sizing in basic scope. This functionality will be completed and developed in the next beta versions.

Articles in HelpSystem:

Version BETA 31 Rev. 0.0.B31

Modules:

Base module, including InstalSystem Manager

  • Introduced a new conception for wall element and the functionality of connecting walls.
  • Indroduced new physical element - the slab.
  • Indroduced new physical element - the roof.
  • Expanded function "Shadow of a storey" for possibility to declare shadows displayed for all stories below.

Radiant heating - panel systems

  • Introduced possibility of calculating thermal output of ceiling/wall panels according to EN 1264 standard.

Articles in HelpSystem:

Version BETA 30 Rev. 0.0.B30

Modules:

Base module, including InstalSystem Manager

  • Allowed to control the content of diagnostic messages using the checkbox "Messages for selected components" on the list of filters in the diagnostics window.
  • Introduced the possibility to handle by the distribution system mail domains with the sign "-".

Radiant heating - panel systems

  • Taken into account results for panels in the radiant heating general results.
  • Introduced the presentation of panels connection points on 3D view.

Articles in HelpSystem:

Version BETA 29 Rev. 16.5.1

Modules:

Base module, including InstalSystem Manager

  • Allowed handling of mail domains containing sign "-" by the licence distribution system.
  • Improved stability of the program during pasting complex installations.
  • Introduced the ability to display the storeys shadow above and below on 2D view.
  • For each element with snapping possibility added the ability to set in the AUTO mode a parameter which predetermine distance from the edge of another inserted element.

Radiant heating - loop systems

  • Corrected a bug related to the manual connecting RHC loop directly to the manifold (without pipe-runs).

Radiant heating - panel systems

  • Allowed the presentation of data in the printout of 'Manifold table' for panel systems installation.

Radiant heating - dry systems

  • Introduced dry system to the neutral catalogue of radiant heating systems.

Articles in HelpSystem:

Version BETA 28 Rev. 16.4.1

Modules:

Base module, including InstalSystem Manager

  • Improved the automatic snapping of pipe-runs for the ORTO mode.
  • Improved the function of rooms interpretation for files imported from InstalSystem 4 package.
  • Introduced the ability to insert into the project construction elements: Wall, Window, Door, Opening in wall.

Radiant heating - panel systems

  • Introduced the possibility to insert into the project element Ceiling false panel (panel with no connection).
  • Added the cooling result card for panel installation: General results cooling.
  • Included elements: Wall panel and Ceiling panel in results card: General results heating.

Version BETA 27 Rev. 16.3.1

Modules:

Base module, including InstalSystem Manager

  • Improved function 'automatically connect terminal units'.
  • Made available the ability to configure the buttons to select a group of elements (SHIFT and CTRL).
  • Introduced possibility of selecting 'None' in the climatic data in case of lack of apropriate climatic data catalogue in the program.
  • Added the function of the graphic presentation of the route of flow from a given receiver to the source.
  • Added the function of the graphic presentation of routes flow from the source (manifold, source) to all receivers, which it supplies.

Radiant heating - dry systems

  • Introduced handling underfloor panels which lead the pipes in dry systems of radiant heating.

Version BETA 26 Rev. 16.2.1

Modules:

Base module, including InstalSystem Manager

  • Improved saving files in a network location.
  • Introduced the possibility to choose the source for which you want to appear the critical circuit.

Version BETA 25 Rev. 16.1.1

Modules:

Base module, including InstalSystem Manager

  • Added function that allows automatically connect terminal units.
  • Added possibility of quick creating rectangular room with sides parallel to the X, Y by drawing diagonal of the room.
  • The problem with sending Problem Report Form is eliminated.

Radiant heating - panel systems

  • Added function that allows connect panels in series.
  • Introduced the possibility to design heating/cooling installations using ceiling/wall panels (including radiant steel ceiling panels).
    Attention! Required upgrade to the configuration with the new module (InstalSystem Manager - tab "Upgrade").

Articles in HelpSystem:

Version BETA 24 Rev. 15.12.1

Warning! For this version of the program the reinstallation is necessary.

Modules:

Base module, including InstalSystem Manager

  • Improved stability and quality of the program.

Radiant heating - loop systems

  • Added a message about the lack of possibility for editing automatically generated pipe feeds/RHC loops.
  • Standarized the content of data table for heating/cooling zones at various ranges of editing.
  • Introduced permanent visibility of the field Pipe laying pattern in the data table for heating/cooling zones.
  • Fixed an error that occurs while connecting pipe feeds route to the heating/cooling zone.

Articles in HelpSystem:

Version BETA 23 Rev. 15.11.1

Modules:

Base module, including InstalSystem Manager

  • Fixed the problem with sending the Problem report form.
  • Added icons for the .isproj files displayed in the InstalSystem Manager and in the Windows Explorer's window.
  • The scope of the displayed catalogues in the general data has been adapted to the available project scope for the package.

Radiant heating - loop systems

  • Changed the designation of nodes in the grid which supports the manual drawing of the loop.
  • Added message box indicating the inability to remove the RHC loop.

Heating network with balancing

  • Fixed the automatic sizing of manifolds' cabinets.
  • Improved the propagation of the default data for manifold cabinet.

Articles in HelpSystem:

Version BETA 22 Rev. 15.10.1

Modules:

Base module, including InstalSystem Manager

  • Added graphical rulers (horizontal and vertical) to help verify the scale of loaded underlay.
  • Improved ORTO and AUTO modes.
  • Fixed the problem with sending error report form after crash of the program.
  • Improved overall stability and quality of the program by eliminating the reported errors.

Articles in HelpSystem:

Version BETA 21 Rev. 15.9.2

Modules:

Base module, including InstalSystem Manager

  • Modified the way of importing base drawing files.
  • Added a Select components in rectangle function under the left mouse button.
  • Improved acting of ORTO mode when moving objects.
  • Accelerated loading of the newly created or saved again files, as a consequence the files created on previous versions may load slower.

Radiant heating - loop systems

  • Added the possibility of parallel connection of several RHC loop to one common outlet from the manifold.
  • Introduced balance diagnostics of the RHC loop connected to the manifold with not integrated balancing valves, and the possibility of adding on the pipe-runs valves which are balancing these objects.

Heating network with balancing

  • Added the possibility to use multi-circuit heating floor zone.
  • Introduced balance diagnostics of the circuits by the heating floor zones in the systems without the manifold.
  • Added the possibility to supply multi-circuit heating floor zone from several manifolds.
  • Introduced the possibility of supplying heating/cooling zones directly from the virtual or graphical source, without the usage of a manifold.

Articles in HelpSystem:

Versão BETA 16.1 Rev. 15.5.17

Módulos:

Módulo base, incluíndo Gestor InstalSystem

  • Adicionada nova ferramenta para pesquisar e selecionar ítens no projeto.
  • Melhorada a importação e exportação de bases.
  • Introduzido o controlo do intervalo de impressão que é baseado no intervalo de edição e nos estilos dos elementos.
  • Introduzida a possibilidade de sublinhar e selecionar elementos do projeto para os quais as mensagens na lista de diagnóstico referem.
  • Adicionada a possibilidade de sublinhar os elementos da folha de trabalho formando o circuito de recetor especificado a partir desta folha de trabalho.

Aquecimento radiante - sistemas em circuito

  • Melhorada a funcionalidade de geração automática de tubos de alimentação.

Artigos em HelpSystem:

Versão BETA 15.1 Rev. 15.4.21

Âmbito inicial dos módulos:

  • Módulo base, incluíndo Gestor InstalSystem
  • Aquecimento radiante - sistemas em circuito
  • Modo de arrefecimento para sistemas radiantes
  • Rede de aquecimento com balanceamento
  • Interface BIM (gbXML)

Estado inicial dos artigos em HelpSystem

Categoria:InstalSystem 5 Categoria:INFORMAÇÃO DO PRODUTO